Rasha M. Ahmed

Publications
  • Research Article
    Evaluation of Different Thromboplastins and Coagulometers on International Normalize Ratio (INR) Readings for Patients under Stable Oral Anticoagulant Therapy
    Author(s): Rasha M. Ahmed and Abdel Rahim M. MuddathirRasha M. Ahmed and Abdel Rahim M. Muddathir

    Background: Variations between various thromboplastin preparations have in the past led to decreased accuracy of INR readings. Because thromboplastin reagents vary widely in composition and manner of preparation, their sensitivity in monitoring oral anticoagulant therapy also vary widely. This study aimed to evaluate different thromboplastins and coagulometers on INR reading for patients under stable oral anticoagulant therapy. Materials and Methods: This was descriptive cross-sectional study; it was conducted in three hospitals (Alshaab teaching hospital, Khartoum teaching hospital, and Turkish hospital). A total of 50 citrated platelets poor plasma samples were collected from 50 Sudanese patients under stable oral anticoagulant therapy then prothrombin time (PT) and INR measurements were performed on three separated laboratories, using different coagulometers and thromboplas.. View More»
    DOI: 10.4172/2155-9864.1000313

    Abstract PDF